Calibration cycle of combustible gas detection alarm

SINO Testing Services

| 2025-02-18|Return

The calibration cycle for combustible gas detection alarms is usually once a year.

According to the national standard JJG 693-2011 "Combustible Gas Detection Alarm", the calibration cycle of combustible gas alarms generally does not exceed one year. This means that under normal circumstances, a comprehensive inspection and testing of combustible gas alarms is required once a year to ensure that their performance indicators meet relevant requirements. ?

Factors affecting the calibration cycle
Manufacturer's requirementsCombustible gas alarms from different manufacturers may have different inspection cycle requirements. Therefore, when purchasing equipment, one should carefully review the product manual to understand the specific requirements of the manufacturer.
Equipment usage environmentThe usage environment of the alarm will directly affect its inspection cycle. If the equipment is exposed to environments with high concentrations of harmful gases, high humidity, high or low temperatures for a long time, its inspection cycle may be correspondingly shortened.
Equipment maintenance statusThe maintenance status of the equipment is also an important factor affecting the inspection cycle. If the device faces long-term problems such as battery shortage and sensor aging, its inspection cycle will also be correspondingly shortened.

Verification cycle under special circumstances

In high-risk areas or key locations such as chemical and petroleum flammable and explosive sites, it is recommended to shorten the testing cycle appropriately according to the actual situation, such as conducting testing every six months or even every quarter, to ensure safety and security.

Testing content and methods

Regularly inspect the probes of industrial and commercial alarm devices every year, mainly to check whether the indication error, repeatability, drift, and response time of the alarm device meet the standards, and issue a testing report. At the same time, check whether the installation position of the alarm is appropriate and whether it is disturbed by other devices.


Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
Service Hotline
18924609560
點擊這里給我發消息 1354407946
點擊這里給我發消息 1354407946
主站蜘蛛池模板: 在线免费看a | 国产精品99久久 | 福利视频网 | 亚洲一区二区久久 | 中文字幕一区二区三 | 久久青| 奇米色欧美一区二区三区 | 韩国三级中文字幕hd久久精品 | 国产精品久久一区二区三区 | 欧美一区二区三区在线视频 | 色婷婷久久一区二区三区麻豆 | 亚洲精品免费视频 | 国产成人精品一区二区视频免费 | 色婷婷久久久swag精品 | 日本一区二区高清不卡 | 99久久精品一区二区 | 天天草草草 | 久久久中文字幕 | 色综合99 | 国产精品污www在线观看 | 狠狠天天 | 日韩第一页 | 四虎免费在线播放 | 国产精品久久九九 | 国产视频久久精品 | 精品av| 欧美成人毛片 | 中文字幕视频在线观看 | 亚洲一区欧美一区 | 国产三区在线成人av | 日韩一区二区三区视频 | 久久精品中文字幕 | 国产一区二区视频在线 | 欧美欧美欧美 | 亚洲骚片| 国产高清精品一区二区三区 | 欧美激情在线观看 | 一区二区久久 | 北条麻妃99精品青青久久 | 国产小视频在线观看 | 亚洲综合区 |