在线国产精品视频_成人看片在线观看_性色av一区二区三区_欧美精品一区二区三区在线播放_亚洲欧洲一级片_91一区二区

Scan code consultation:
0755-2102 2109
Service
Current location: Home Service Ex inspection
Basic requirements for the safety of explosion-proof electrical equipment in hazardous areas | Explosion proof testing

SINO Testing Services

| 2022-03-28|Return

Installing and using explosion-proof electrical equipment in hazardous and explosive areas is the most basic requirement for safety.

But what issues should be noted when selecting and installing explosion-proof electrical equipment? Below, Zhongnuo Testing will share a few points with everyone.

1、 The selection of explosion-proof electrical equipment should meet the requirements of hazardous areas

(1) Electrical equipment for explosive hazardous environments should be selected based on the hazard level of the installation location, the group and level of hazardous substances, the type and usage conditions of electrical equipment.

(2) The group and level of the selected electrical equipment should not be lower than the group and level of hazardous substances in the environment.

(3) When there are two or more hazardous substances, the one with the higher degree of danger should be selected.

(4) Gas explosion-proof electrical equipment and dust explosion-proof electrical equipment cannot be mixed.

(5) In explosive hazardous environments, portable electrical equipment should be minimized or avoided as much as possible.

(6) Try to install as few pin sockets as possible.

2、 The installation and laying of explosion-proof electrical equipment comply with regulatory requirements

(1) In explosive and fire hazardous environments, the installation location, laying method, wire material, connection method, etc. of electrical equipment circuits should be adapted to the regional hazard level.

(2) Explosion accidents caused by sparks generated by exposed or aged cables should be avoided.

3、 Technical requirements for explosion prevention in hazardous and explosive areas

1. Eliminate or reduce explosive mixtures

(1) Eliminating or reducing explosive mixtures includes adopting enclosed operations to prevent the leakage of explosive mixtures;

(2) Clean up the accumulated dust on site and prevent the accumulation of explosive mixtures;

(3) Design a positive pressure chamber to prevent explosive mixtures from entering areas with ignition sources;

(4) Take open work or ventilation measures to dilute explosive mixtures;

(5) Fill hazardous spaces with inert or inert gases to prevent the formation of explosive mixtures.

2. Isolation

(1) Dangerous equipment should be installed in separate rooms and sealed off on partition walls.

(2) Electric motor partition transmission, lighting fixtures, and glass window lighting are all isolation measures.

3. Eliminate ignition source

(1) Select electrical equipment and design electrical circuits based on the characteristics of explosive hazardous environments and the level and group of hazardous materials.

(2) Ensure the safe operation of electrical equipment and electrical circuits. Safe operation includes current, voltage, temperature rise, and temperature not exceeding the allowable range, including good insulation, good connection and contact, overall integrity, cleanliness, clear markings, etc.

4. Grounding measures

(1) Attention should be paid to grounding in explosive hazardous environments: all uncharged metal objects should be equipotential bonded;

(2) If low voltage is distributed by the grounding system, TN-S system should be used instead of TN-C system;

(3) If the low voltage is distributed by an ungrounded system, an IT system should be used and equipped with protective devices that can automatically cut off the power supply in case of severe leakage or alarm devices that can emit dual signals of sound and light.

4、 Regularly conduct on-site explosion-proof safety inspections of hazardous and explosive areas

According to the AQ 3009-2007 "Explosion proof Specification for Electrical Safety in Hazardous Areas" standard, explosion-proof electrical equipment in use must be entrusted to a testing center with explosion-proof professional qualifications for testing the performance, installation, maintenance, etc. of explosion-proof electrical appliances at least once every 3 years. Any non compliant items must be rectified in a timely manner, and the inspection report and rectification situation must be filed with the safety production supervision and management department.Regular on-site inspections of explosion-proof electrical equipment in use can promptly identify problems in hazardous areas and maximize the containment and elimination of potential accidents. This is not only a requirement from the safety production department, but also an emphasis on the safety of one's own life and property by the enterprise.


Safety is no small matter, and electrical safety in explosive hazardous areas is related to the safety production of enterprises and the country. Pay attention to safety and explosion prevention!



Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
Service Hotline
18924609560
點擊這里給我發消息 1354407946
點擊這里給我發消息 1354407946
主站蜘蛛池模板: 午夜私人影院 | 黄色片视频在线观看 | 婷婷综合 | 成人片免费看 | 黄色国产一级视频 | 一区二区三区 在线 | 国产精品原创av片国产免费 | 亚洲高清一区二区三区 | 欧美一性一交 | 中文字幕视频在线 | 中文字幕在线观看不卡视频 | 精品欧美乱码久久久久久1区2区 | 999国产| 欧美日本一区 | 国产高清在线看 | 超碰天天 | 国产精品久久a | 国产黄色在线免费看 | 久久久成 | 精品伊人久久 | 日韩国产 | 丁香婷婷久久久综合精品国产 | 秋霞av电影 | 欧洲视频一区二区三区 | 久久亚洲一区 | 天堂精品 | 五月婷婷中文 | 亚洲福利一区二区 | 日韩精品一区二区三区第95 | 欧美精品导航 | 欧美性猛交一区二区三区精品 | 久久久精品久久久久 | 毛片免费观看 | 国产日韩在线视频 | 国产精品久久久99 | 干狠狠| 久久久精品| 国产精品美女久久久久久久久久久 | 亚洲a视频| 中文字幕成人影院 | 午夜国产一级 |